Beta Structure
|
|
|
Material
|
Standards
|
Properties
|
Other
|
|
Framework
|
Aluminium
|
Framework Engineered to meet BS6399
|
Alloy designation 6061 (AlMgSiCu) and 6082 (AlMgSi1)
|
20% of all aluminium originates from recycled sources
Profiles: 30m width 5m eave height 400/115 Length 4586mm 25m width 5m eave height 320/115 Length 4586mm 25m width 6m eave height 400/115 Length 5586mm 20m width 4m eave height 320/115 Length 3586mm 20m width 5m eave height 320/115 Length 4586mm 20m width 6m eave height 320/115 Length 5586mm 15m width 5m eave height 285/110 Length 4586mm 15m width 6m eave height 285/110 Length 5586mm 10m width 5m eave height 210/110 Length 4586mm
|
| Column Legs |
Aluminium |
Engineered to meet BS6399 |
Alloy designation 6061 (AlMgSiCu) and 6082 (AlMgSi1) |
| Cladding (Insulated) |
Laminated horizontal steel cladding Galvanised outer steel layer 0.63mm, inner layer 0.50mm Pre-painted PES 25?m outside, 15?m inside. 60mm/30mm polyurethane foam insulating layer
|
EN13501-1 (Reaction to Fire C-s3,d0) |
U Value
0.41 W/m2K @ 60mm 0.80 W/m2K @ 30mm
|
Available in a range of profiles and RAL colours |
| Cladding (Standard) |
Profiled steel 0.63mm thick external faces pre-lacquered 25 micron thick. |
|
|
Available in a range of profiles and RAL colours. |
| Roller Shutter Doors |
Type S75E Power operated Industrial Duty Roller Shutter. with galvanised steel endlocks, rivets, side guides and bottom rail.
|
M2 fire classification Tested to BS 5438 and achieving BS 7837
|
|
Where Electrically Operated door is required, 3 phase power and earth required from 6 Amp powered isolator with 5 pin CEE socket between 600 and 1700mm from floor level within 1000mm of door on motor side |
| Roof Membrane |
PVC/ Polyurethane membrane 590g/m2 “fluotop” dirt repellent coating Resistant to mould, sea spray and UV
|
M2 fire classification Tested to BS 5438 and achieving BS 7837
|
U Values
Standard roof 6.40 W/m2K Insulated roof 2.33 W/m2K
|
|
| Other Components |
Galvanised Steel |
BS6399 |
|
Fixings, bracing cables, baseplates, reinforcement members |
| Anchoring |
Usually by M20/170HAS rods into a pre-prepared concrete base using HVU Adhesive |
Tested post installation to ensure that necessary loadings are achieved. Re BS6399 |
Design Resistance of 62.9kN Tensile Load and 54.0kN Shear Load per rod |
Where fixing by HAS rods and HVU Adhesive is not possible, a number of different anchoring methods are available – all tested to ensure that the requirements of BS6399 are met. |