Tech Data & Installation

Technical Data

Alpha Structure

 

Material

Standards

Properties

Other

Framework

Anodised Aluminium

Framework Engineered to meet BS6399

Alloy designation 6061 (AlMgSiCu) and 6082 (AlMgSi1)

20% of all aluminium originates from recycled sources

Column Legs

Anodised Aluminium

Engineered to meet BS6399

Alloy designation 6061 (AlMgSiCu) and 6082 (AlMgSi1)

Profiles:
Lateral and Gable Columns: MU 172 Anodised aluminium with steel reinforcement’s rectangular profile 220mm x 110mm x 3mm.
Corner: MU 173 cross profile 220 x 220 x 3mm.
Internal: MU 173 cross profile 220 x 220 x 3mm.

Cladding (Insulated)

Laminated horizontal steel cladding. Galvanised outer steel layer 0.63mm, inner layer 0.50mm
Pre-painted PES 25m outside, 15m inside. 60mm polyurethane foam insulating layer

EN13501-1 (Reaction to Fire C-s3,d0)

U Value

0.41 W/m2K @ 60mm
0.80 W/m2K @ 30mm

Available in a range of profiles and RAL colours.
These panels can be easily cut to allow for the fitting of, for instance, patio doors to match the specification of a show apartment within a marketing suite or windows for an office

Glazed Panels

60mm section aluminium with 6mm “sekurit” glass panel

(double glazing two panels of 6mm “sekurit” with a 4mm void)

All glass is 6mm “sekurit” safety glass to BS EN 12150

U-Values

Single Glazing 5.70 W/m2K
Double Glazing 2.70 W/m2K

Double glazed panels are 2.7m or 1.0m high
Glazing is always in a run of 5m or a multiple of 5m

Glazed Doors

Aluminium frame with 6mm “sekurit” Glazing.

All glass is 6mm “sekurit” safety glass to BS EN 12150

U-Values

Single Glazing 5.70 W/m2K
Double Glazing 2.70 W/m2K

Fits into ground beam to create level threshold 160mm above ground level
Lockable (2 keys provided on handover)
2 way opening with Panic bar on one side and Self Closers

Roof Membrane

PVC/Polyurethane membrane
1050g/m2 “fluotop” dirt repellent coating
Resistant to mould, sea spray and UV

M2 fire classification
Tested to BS 5438 and achieving BS 7837

U Values

Single roof 6.40 W/m2K
Double (insulated) roof 2.33 W/m2K

Roofs are available in two distinct designs: Barrel Vaulted and Pyramidal

Other Components

Galvanised Steel

BS6399

 

Fixings, bracing cables, baseplates, reinforcement members

Anchoring

Usually by M20/170HAS rods into a pre-prepared concrete base using HVU Adhesive

Tested post installation to ensure that necessary loadings are achieved - BS6399

Design resistance of 62.9kN tensile load and 54.0kN shear load per rod

Where fixing by HAS rods and HVU Adhesive is not possible, a number of different anchoring methods are available – all tested to ensure that the requirements of BS6399 are met.

 

Installation

Stage 1 - Base plates anchored

1. Base plates anchored to the ground using chemical bolts and flooring assembled.

Stage 2 - Roof assembled

2. Roof assembled on the ground removing the need and hazard of working at height

Stage 3 - Legs attached

3. Legs attached then roof and frame lifted by
crane

Stage 4 - Legs and counterbracing secured to base plates

4. Legs and counterbracing secured to base plates

Stage 5 - Glazing, cladding and doors fitted

5. Glazing, cladding and doors fitted.

 

/ ©2010 Useful Structures Ltd. All Rights Reserved. / Bookmark This Site / / Privacy policy /   Website Design By Zarr