Useful Structures. Fully relocatable structures, off site construction, adaptable buildings.
/ HOME / ABOUT US / NEWS / TESTIMONIALS / BROCHURES / QUOTE / GALLERY / CONTACT US /  
/ Sales and Marketing Suites
/
/
/
/
/
/
/
/
/ Tech Data & Installation
/
/
/ Warehousing and Logistics
/ Sports & Leisure Facilities
/ Waste Management
/ Education Facilities
/ Office Space
/ Larger Structures
/ Offsite Construction Pods

Tech Data & Installation

 
Technical Data

Landmark Structure

 

Material

Standards

Properties

Framework Welded Rectangular Section - Hot Formed to form the main structure with 100mm x 1.6mm Structmet Framing System. Rectangular Section - Hot Formed to BS EN 10210:1997

Structmet Framing System Steel grade S280 or S350 to BS EN 10326.
Rectangular Section - Hot Formed rust protected with Red Oxide.
Structmet Framing System Grade S390 pre-galvanised in accordance with BS EN 10326 to provide a minimum zinc coating of 275g/m².
Cladding (Insulated) Kingspan KS1000FL Sirius HPS 200 80mm insulated panel. 0.30W/m²K Rw = 25dB. Steel and aluminium outer and inner facings have Class 1 surface spread of flame to BS 476: Part 7: 1987, and are Class 0, as defined by Building Regulations. 0.30W/m²K Rw = 25dB.
Glazed Panels 24mm thick DGU’s 2x 6mm toughened glass panel with 12mm air cavity All glass is Toughened to BS6262 U-Values centre pane
Double Glazing 2.70 W/m2K
Glazed Doors Non Thermally broken profiles with 24mm thick DGU’s 2x 6mm toughened glass panel with 12mm air cavity All glass is Toughened to BS6262 U-Values centre pane
Double Glazing 2.70 W/m2K

Internal Fit Out

Internal Walls 70mm x 1.6mm Structmet Framing System with 12.5mm Knauf Moistureshield Plasterboard Structmet Framing System, Steel grade S280 or S350 to BS EN 10326. Structmet Framing System Grade S390 pre-galvanised in accordance with BS EN 10326 to provide a minimum zinc coating of 275g/m².
Ceiling 12.5mm Knauf Moistureshield Plasterboard    
Floor 22mm Moisture Resistant Chipboard, Triaso Super 10 Insulation    
Internal Stair      
External Stair      
Lighting Kitchenette & WC: 28w 2d Flash Dar Lighting FLA5050/2D    
 General: JCC JC94007CH LV eyeball    
 Emergency Lighting: Robus 8W Non –Maintained Emergency Light    IP65
 Electrical  Click Accessories    
 Sockets + Wiring      
 Heating/AC  Digitemp WHP245 Air Conditioning Heating Unit    
Kitchenette Howdens Greenwich White
WorkTop: 40mm Stardust Prima
Sink: Aegean 1.5 bowl
Tap: Reginox RF6
Wall Tiles Mayolica Cornito Blanco 20 x 20 with Mayolica Cornito Gris 4 x 20 Border
Floor Tiles: Fanal Seul Perla
Trim: S/Steel
Grout: White
Wall Paint: White Matt Emulsion
Ceiling Paint: White Matt Emulsion
   
WC Armitage Sandringhm btw pan
Orion Plus Seat
Armitage Sandringham 560mm 1 tap hole basin
Armitage Sandringham Ova
Pedestal
Sandringham Basin Monobloc with PUW p
Cistern Cover: Nuance Alabaster
Wall Tiles Mayolica Cornito Blanco 20 x 20 with Mayolica Cornito Gris 4 x 20 Border
Floor Tiles: Fanal Seul Perla
Grout: White
Wall Paint: White Matt Emulsion
Ceiling Paint: White Matt Emulsion
Extract Fan:Manrose XT 100T Fan Timer 100mm
   

 

Installation

 Stage 1 - Off-site contructed module arrives on lorry

Fully shrouded and protected
off-site constructed module arrives on lorry

Stage 2 - Module lifted from transporter

Module is lifted from transporter
and manoeuvred into
position

Stage 3 - Second storey positioned in the same way

Where a second storey is needed, it is lifted and positioned in the
same way

Stage 4 - Carefully located on top of the ground floor unit

. . . carefully located on top of the ground
floor unit

Stage 5 - Landmark unit awaiting connection to mains services

Two storey Landmark unit awaiting connection
to mains services and occupation

 

/ ©2010 Useful Structures Ltd. All Rights Reserved. / Bookmark This Site / / Privacy policy /   Website Design By Zarr