Alpha Structure
|
|
|
Material
|
Standards
|
Properties
|
Other
|
|
Framework
|
Anodised Aluminium
|
Framework Engineered to meet BS6399
|
Alloy designation 6061 (AlMgSiCu) and 6082 (AlMgSi1)
|
20% of all aluminium originates from recycled sources
|
|
Column Legs
|
Anodised Aluminium
|
Engineered to meet BS6399
|
Alloy designation 6061 (AlMgSiCu) and 6082 (AlMgSi1)
|
Profiles: Lateral and Gable Columns: MU 172 Anodised aluminium with steel reinforcement’s rectangular profile 220mm x 110mm x 3mm. Corner: MU 173 cross profile 220 x 220 x 3mm. Internal: MU 173 cross profile 220 x 220 x 3mm.
|
|
Cladding (Insulated)
|
Laminated horizontal steel cladding Galvanised outer steel layer 0.63mm, inner layer 0.50mm Pre-painted PES 25?m outside, 15?m inside. 60mm polyurethane foam insulating layer
|
EN13501-1 (Reaction to Fire C-s3,d0)
|
U Value
0.41 W/m2K @ 60mm 0.80 W/m2K @ 30mm
|
Available in a range of profiles and RAL colours. These panels can be easily cut to allow for the fitting of, for instance, patio doors to match the specification of a show apartment within a marketing suite or windows for an office
|
|
Glazed Panels
|
60mm section aluminium with 6mm “sekurit” glass panel
(double glazing two panels of 6mm “sekurit” with a 4mm void)
|
All glass is 6mm “sekurit” safety glass to BS EN 12150
|
U-Values
Single Glazing 5.70 W/m2K Double Glazing 2.70 W/m2K
|
Double glazed panels are 2.7m or 1.0m high Glazing is always in a run of 5m or a multiple of 5m
|
|
Glazed Doors
|
Aluminium frame with 6mm “sekurit” Glazing.
|
All glass is 6mm “sekurit” safety glass to BS EN 12150
|
U-Values
Single Glazing 5.70 W/m2K Double Glazing 2.70 W/m2K
|
Fits into ground beam to create level threshold 160mm above ground level Lockable (2 keys provided on handover) 2 way opening with Panic bar on one side and Self Closers
|
|
Roof Membrane
|
PVC/Polyurethane membrane 1050g/m2 “fluotop” dirt repellent coating Resistant to mould, sea spray and UV
|
M2 fire classification Tested to BS 5438 and achieving BS 7837
|
U Values
Single roof 6.40 W/m2K Double (insulated) roof 2.33 W/m2K
|
Roofs are available in two distinct designs: Barrel Vaulted and Pyramidal
|
|
Other Components
|
Galvanised Steel
|
BS6399
|
|
Fixings, bracing cables, baseplates, reinforcement members
|
|
Anchoring
|
Usually by M20/170HAS rods into a pre-prepared concrete base using HVU Adhesive
|
Tested post installation to ensure that necessary loadings are achieved. Re BS6399
|
Design resistance of 62.9kN tensile load and 54.0kN shear load per rod
|
Where fixing by HAS rods and HVU Adhesive is not possible, a number of different anchoring methods are available – all tested to ensure that the requirements of BS6399 are met.
|